Esxi 5.5 patch 5 re-release

Esxi 5.5 patch 5 re-release - Free Download

For more information about the sequence in which vSphere environments need to be updated, refer, KB Features and known issues of ESXi 5. Release notes for earlier releases of ESXi 5. For ESXi versions 4. For more information about VDDK, see http: To determine which devices are compatible with ESXi 5. Some devices are deprecated and no longer supported on ESXi 5. During the upgrade process, the device driver is installed on the ESXi 5. It might still function on ESXi 5. For a list of devices that have been deprecated and are no longer supported on ESXi 5.

To determine which guest operating systems are compatible with vSphere 5. Virtual machines that are compatible with ESX 3. Virtual machines that are compatible with ESX 2. To use such virtual machines on ESXi 5. See the vSphere Upgrade documentation. Although the installations are straightforward, several subsequent configuration steps are essential. Read the following documentation:. Architectural changes between ESXi 5. For information about upgrading your host with third-party customizations, see the vSphere Upgrade documentation.

During an installation or upgrade, the installer checks the compatibility of the host CPU with vSphere 5. If your host hardware is not compatible, a purple screen appears with a message about incompatibility.

You cannot install or upgrade to vSphere 5. For more information about the sequence in which vSphere environments need to be updated, refer KB The copyright statements and licenses applicable to the open source software components distributed in vSphere 5.

You can also download the source files for any GPL, LGPL, or other similar licenses that require the source code or modifications to source code to be made available for the most recent available release of vSphere. Third party browsers that add support for Adobe Flash on the Linux desktop OS might continue to function.

VMware vCenter Server Appliance. Beginning with vSphere 5. For resolution on incompatibility and general guidelines, refer KBs and This release contains all bulletins for ESXi that were released earlier to the release date of this product.

See the VMware Download Patches page for more information about the individual bulletins. For information on patch and update classification, see KB Unable to create or open a LOCK file.

No space left on device. LOCK for process python because the visorfs inode table is full. LOCK for process hostd because the visorfs inode table is full. The OS X The spurious warning should be ignored. The issue occurs if the following guest files exist on the Virtual Machine: New known issues documented in this release are highlighted as New Issue.

You need to update to latest vCenter Server 5. The issue occurs if the your glibc version is older than version 2. However, no core dump partition is created. When you do so, a 2. If you use the --ignoressd option with the installorupgrade command, the installer displays a warning that this is an invalid combination. The installer continues to install ESXi on the SSD instead of stopping the installation and displaying an error message. To use the --ignoressd option in a scripted installation of ESXi, use the install command instead of the installorupgrade command.

Delay in Auto Deploy cache purging might apply a host profile that has been deleted After you delete a host profile, it is not immediately purged from the Auto Deploy. As long as the host profile is persisted in the cache, Auto Deploy continues to apply the host profile. Any rules that apply the profile fail only after the profile is purged from the cache.

The cmdlet shows the string deleted in the rule's itemlist. You can then run the Remove-DeployRule cmdlet to remove the rule. Applying host profile that is set up to use Auto Deploy with stateless caching fails if ESX is installed on the selected disk You use host profiles to set up Auto Deploy with stateless caching enabled.

When you apply the host profile, an error that includes the following text appears. Expecting 2 bootbanks, found 0. Select a different disk to use for stateless caching, or remove the ESX software from the disk.

If you remove the ESX software, it becomes unavailable. Installing or booting ESXi version 5. When you install or boot ESXi 5. After upgrade from vCenter Server Appliance 5. In the appliance management interface, the vCenter Single Sign-On is listed as not configured. As a result, vMotion and FT Logging are restored to the default setting disabled. Perform an interactive or scripted upgrade, or use vSphere Update Manager to upgrade hosts.

If you use the esxcli command, apply vMotion and FT Logging settings manually to the affected VMkernel port group after the upgrade.

When you upgrade vSphere 5. You cannot reset the value for these settings to the default without completely reinstalling ESXi. The upgrade resets all such values. The vSphere Web Client lets you configure more virtual functions than are supported by the physical NIC and does not display an error message In the SR-IOV settings of a physical adapter, you can configure more virtual functions than are supported by the adapter.

For example, you can configure virtual functions on a NIC that supports only 23, and no error message appears. After the host reboots, the NIC is configured with as many virtual functions as the adapter supports, or 23 in this example. The message that prompts you to reboot the host persists when it should not appear. Reduce the number of virtual functions associated with the affected virtual machine before starting it. Disable the native driver for Emulex BladeEngine 3 devices on the host.

For more information, see VMware KB An LACP port channel is configured on the physical switch. When a host that runs ESXi 5. The number of ports is based on the number of virtual machines that the host can run.

You do not have to configure the number of switch ports on such hosts. NIC hardware might stop responding with an hardware error message The NIC hardware might occassionally stop responding under certain circumstances with the following error message in the driver logs: Detected Hardware Unit Hang The issue is observed with some new ee devices like , i, i and i Host Profile remediation fails with vSphere Distributed Switch Remediation errors might occur when applying a Host Profile with a vSphere Distributed Switch and a virtual machine with Fault Tolerance is in a powered off state on a host that uses the distributed switch in that Host Profile.

Move the powered off virtual machines to another host in order for the Host Profile to succeed. Host profile receives firewall settings compliance errors when you apply ESX 4. The compliance check receives firewall settings errors that include the following: No workaround is required. This is expected because the firewall settings for an ESX 4. Due to a bug in this feature, invalid names such as vmhba1 and vmnic32 are sometimes generated.

Rebooting the ESXi host once or twice might clear the invalid device names and restore the original names. Do not run an ESXi host with invalid device names in production.

Renamed tags appear as missing in the Edit VM Storage Policy wizard A virtual machine storage policy can include rules based on datastore tags. If you rename a tag, the storage policy that references this tag does not automatically update the tag and shows it as missing. Remove the tag marked as missing from the virtual machine storage policy and then add the renamed tag. Reapply the storage policy to all out-of-date entities.

When you power on a virtual machine, the operation fails and the following messages appear:. The virtual machine cannot be powered on with an unconfigured disk. When you disable DRS in the vSphere Web Client, you are prompted to save the resource pool structure so that it can be reloaded in the future.

The default extension of this file is. If the file has a custom extension, it appears as disabled when you try to load it. This behavior is observed only on OS X.

esxi 5.5 patch 5 re-release

VMware vSphere Update Manager 5.5 Release Notes

Sleeping for 20 seconds sfcbd: This problem occurs only during the first import of offline patch bundles. Alternatively, you can wait for a timeout 15 minutes by default , and vSphere HA attempts to restart the virtual machine on a different host. Perform the following steps: Power on the virtual machine then power it off again. In such cases, a low cache hit rate with a low cache occupancy is observed, which implies a waste of cache reservation for such VMDKs.

VMware ESXi 5.5 Update 2 Release Notes

The Update Manager server can be installed on the same system as vCenter Server or on a different system. ESXi hosts might fail with a purple screen when you perform X-vMotion ESXi hosts might fail with a purple screen with error messages similar to the following when you perform X-vMotion: Open a command prompt window. An error message similar to the following is displayed:

VMware Product Build Numbers to Update Levels

esxi 5.5 patch 5 re-release

When you open the Compliance view, the error Failed to retrieve data appears. An error similar to the following is written to vmkernel. Visiting Indian Ocean and Reunion Island? Wait at least 15 minutes for the Storage Providers view to be populated again. Failed to configure disk scsi0: UMDS can be installed only on bit Windows operating systems. A Virtual SAN virtual machine in a vSphere HA cluster is reported as vSphere HA protected although it has been powered off This might happen when you power off a virtual machine with its home object residing on a Virtual SAN datastore, and the home object is not accessible. Using Reapply action does not change the status. However, the maximum allowed number of HDDs is seven. Noncompliance messages appear after using Auto Deploy for stateless caching or stateful installs to USB After a host profile is edited to enable stateless caching to the USB disk on the host, the host profile receives compliance errors when attempting to remidiate. If you remove the ESX software, it becomes unavailable. Right-click the virtual machine and select Edit Settings. After a failure in a Virtual SAN cluster, vSphere HA might report multiple events, some misleading, before restarting a virtual machine The vSphere HA master agent makes multiple attempts to restart a virtual machine running on Virtual SAN after it has appeared to have failed. Such configuration could cause network failure and disrupt Virtual SAN internode communication, while vSphere HA internode communication remains unaffected. To determine which guest operating systems are compatible with vSphere 5.